The feasibility of correct NaI gamma-spectrometry activity measurement for each nuclide in 131I, 132I, 133I, 134I, 135I, 133Xe, 135mXe, 135Xe and 222Rn composition is presented. To get this result the special matrix method M3 and SAS Na M3 software were used for spectra processing. SAS Na M3 software was developed for complex NaI gamma-spectra processing. Special algorithms and auxiliary software are used to overcome the problems of the classic spectra processing matrix method. Being used for spectrum processing SAS Na M3 software determines the nuclide composition of the sample, activity of nuclides identified and activities uncertainties. The activity values estimation is made for nuclides not identified in the sample measured but included in SAS Na M3 software nuclides library. The values of minimal detectable activities for NaI ∅3''× 3'' gamma-spectrometer and 1 hour measuring time are ~ 0.6 Bq for 131I, 132I, 133I, 134I and ~ 2 Bq for 135I.

Keywords:
iodine radioactive nuclide, xenon radioactive nuclide, NaI gamma-spectrometer, special matrix method M3 for NaI spectra processing, SAS Na M3 software for NaI spectra processing, SAS Na M3 software
References

1. Tehnicheskoe zadanie na razrabotku mobil'noy radiometricheskoy ustanovki dlya kontrolya ob'emnoy aktivnosti radionuklidov yoda v vozduhe. Utverzhdeno zamestitelem General'nogo direktora po proizvodstvu i ekspluatacii AES OAO «Koncern Rosenergoatom» Kop'evym Yu.V. M., 2010.

2. Antropov S.Yu., Ermilov A.P. Izmerenie aktivnosti I-131 s ispol'zovaniem scintillyacionnogo detektora s PO «Progress». URL: http://www.doza.ru/support/pub/2957/ (data obrascheniya: 13.10.2021).

3. Antropov S.Yu., Ermilov A.P. Izmerenie aktivnosti I-131 s ispol'zovaniem scintillyacionnogo detektora s PO «Progress». URL: http://amplituda.nichost.ru/ru/materials/articles/izmerenieaktivnosti-131i-s-ispolzovaniem-stsintillyatsionnogo-detektora-s-po-progress (data obrascheniya: 13.10.2021).

4. Drovnikov V.V. i dr. Programma «Na Spectra Analysis System» - SAS Na M3 dlya obrabotki slozhnyh scintillyacionnyh spektrov. Nekotorye rezul'taty issledovaniya radionuklidnogo sostava prob dopustimyh sbrosov i dopustimyh vybrosov Novovoronezhskoy AES//ANRI. 2011. N 2(65). C. 31-39.

5. Drovnikov V.V. i dr. Nekotorye rezul'taty opytnoy ekspluatacii gamma-spektrometra NaI PAK-01 v Laboratorii vneshnego radiacionnogo kontrolya NV AES. Radionuklidnyy analiz obrazcov debalansnyh vod i aerozol'nyh vybrosov NV AES. Sbornik materialov 18 ezhegodnogo seminara v NOU DPO «CIPK». Obninsk: «CIPK», 2012. S. 17-35.

6. Drovnikov V.V. i dr. Ocenka vozmozhnosti primeneniya scintillyacionnyh spektrometrov s detektorami NaI dlya operativnogo kontrolya dopustimyh sbrosov i vybrosov AES//ANRI. 2013. N 1(72). S. 66-72.

7. Sovmestnyy otchet MIFI-NVAES. Ekspress-otchet o rezul'tatah slichitel'nyh ispytaniy programmno-apparatnogo kompleksa NaI PAK-01 v LVRK Novovoronezhskoy AES. 16-31 maya 2011.

8. Programma GEANT4. URL: http://geant4.web.cern.ch/geant4/support/userdocuments.shtml (data obrascheniya: 14.10.2021).

9. Gusev N.G., Rubcov P.M., Kovalenko V.V., Kolobashkin V.M. Radiacionnye harakteristiki produktov deleniya. Spravochnik. M.: Atomizdat, 1974.