NEW ALGORITHM FOR UPGRADING OF PORTAL RADIATION MONITORS WITH PLASTIC DETECTORS PART 2. OPTIMIZATION OF VALUES OF ALARMING THRESHOLD AND SMOOTHING
Abstract and keywords
Abstract (English):
The way of improving of traditional algorithm for portal radiation monitors with plastic detectors by optimization of values of alarming threshold and smoothing is discussed in the second part of the article. As the result of such optimization the probability of detection of radioactive sources may be significantly increased and probability of false alarms decreased as well.

Keywords:
portal radiation monitor, smoothing, profile of count rate, suppression of natural radioactive background
References

1. Final Report. ITRAP - Illicit Trafficking Radiation Detection Assessment Program. Austrian Research Centers, Seibesrdorf, 2002.

2. Lukashevich R.V. Primenenie spektrometricheskogo metoda rascheta moschnosti dozy dlya sozdaniya vysokochuvstvitel'nyh obrazcov izmereniya na baze scintillyacionnyh blokov detektirovaniya//Pribory i metody izmereniy. 2017. T. 8, N№3. S. 246-253. 2a. Kozhemyakin V.A. i dr. Nezavisimaya avtomatizirovannaya sistema radiacionnogo monitoringa okruzhayuschey sredy. XIV mezhdunarodnoe soveschanie «Problemy prikladnoy spektrometrii i radiometrii». Tezisy dokladov. M., 4-6 oktyabrya, 2017.

3. K.E. Duftschmid. «Gamma Spectrometric Techniques for Suppression of „Innocent Alarms“ in Border Monitoring». WCO conference, Budapest, 22-24 September, 2003.

4. R.T. Kouzes et al., «The Use of Energy Windowing to Discriminate SNM from NORM in Radiation Portal Monitors», Nuclear Instruments and Methods in Physics Research. 2006, PNNL-SA-44860.

5. R.T. Kouzes et al. «Improved Performance of Energy Window Criteria Obtained Using Multiple Windows at Radiation Portal Monitoring Sites». Proceedings of INMM 47th Annual Meeting. 16-20 July, 2006.

6. A. Stavrov et al. «New opportunities of portal monitors with plastic scintillation detectors (ASIA-New. New Advanced Source Identification Algorithm)». NATO Advanced Research Workshop. Preparedness for Nuclear and Radiological Threats. 18-20 November, 2014, Los Angeles, USA.

7. A. Stavrov et al. «Real breakthrough in detection of radioactive sources by portal monitors with plastic detectors and New Advanced Source Identification Algorithm (ASIA-New)». ANIMMA 2015, Advancements in Nuclear Instrumentation. 20-24 April, 2015, Lisbon.