The article presents gamma images of containers and casks with radioactive waste, obtained using a gamma scanner with an anticollimator. Such images can be used to analyze the radionuclide composition of radioactive waste and to obtain information on the spatial distribution of activity in casks and containers of large sizes
gamma scanner, gamma image, radioactive waste, few projections computed tomography
1. K. Vetter, L. Mihailescu, K. Nelson, J. Valentine, D. Wright, «Gamma-ray Imaging Methods. LLNR Report UCRL-TR-225239». DOI:https://doi.org/10.2172/1036848, 2006.
2. Teverovskiy Yu.L. Pribory i metody polucheniya vizual'nogo izobrazheniya istochnikov gamma-izlucheniya na ob'ektah atomnoy energetiki. Chast' 1//ANRI. 2020. №2(101). DOI:https://doi.org/10.37414/2075-13382020-101-2-18-30, 2020.
3. K.P. Ziock, «Principles and applications of gamma-ray imaging for arms control», Nucl. Instrum. Methods Phys. Res. A, vol. 878, pp. 191-199, 2018.
4. Ivanov O.P., Kovalev V.M., Stepanov A.V., Stepanov V.E., Stepanov E.A. Opyt primeneniya portativnyh gamma-kamer (gamma-vizorov) v rabotah po vyvodu iz ekspluatacii i reabilitacii OIAE// ANRI. 2022. № 1(108). S. 19-35.
5. Stepanov V.E. i dr. Distancionno upravlyaemyy kollimirovannyy detektor dlya izmereniya raspredeleniy radioaktivnyh zagryazneniy//Atomnaya energiya. 2010. T. 109. № 2. S. 82-84.
6. Gamma-skaner RadSearch (ANTECH): Series G3050. URL: https://www.antech-inc.com/service/ gamma-camera-surveys/(data obrascheniya: 4.06.2025).
7. O.P. Ivanov, V.N. Potapov, I.A. Semin et al, «4p Spectrometric Gamma-Ray Scanner with AntiCollimator», 2019, IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), Manchester, UK, 2019, pp. 1-5. DOI:https://doi.org/10.1109/NSS/MIC42101.2019.9059820.
8. Ivanov O.P., Ignatov S.M., Potapov V.N., Samoylova M.A., Semin I.A. Gamma-skaner s antikollimatorom dlya vizualizacii istochnikov gamma-izlucheniya//Pribory i tehnika eksperimenta. 2021. № 2. S. 115-120.
9. Tarasko M.Z. Ob odnom metode resheniya lineynyh sistem so stohasticheskimi matricami, FEI im. A.I.Leypunskogo. Obninsk. 1969. Preprint FEI-156.
10. W.H. Richardson, «Bayesian-Based Iterative Method of Image Restoration», JOSA, no. 62, pp. 55-59. 1972.
11. L.B. Lucy, «An iterative technique for the rectification of observed distributions», Astronomical Journal, no. 79, pp. 745-754, 1974.
12. K.-Sh. Chuang, et al. «A maximum likelihood expectation maximization algorithm with thresholding», Computerized Medical Imaging and Graphics, vol. 29, no. 7, pp. 571-578, Nov. 2005. DOI:https://doi.org/10.1016/j. compmedimag.2005.04.003.
13. O. Ivanov, V. Potapov, I. Semin. «The Method to Improve the Angular Resolution of the Portable Gamma Camera with Pinhole Collimator», NSS-MIC, Oct. 2016, Strasbourg, France. Paper N08-4, 2016. DOI:https://doi.org/10.1109/NSSMIC.2016.8069704.
14. O. Gal, F. Jean, F. Laine, C. Leveque. «The CARTOGAM portable gamma imaging system». IEEE Transactions on Nuclear Science, 47(3), pp. 952-956. July 2000. DOI:https://doi.org/10.1109/23.856725.
15. Potapov V.N., Simirskiy Yu.N., Ivanov O.P. i dr. Ocenka metodicheskoy pogreshnosti izmereniya aktivnosti RAO raznymi sposobami dlya transportnyh konteynerov bol'shogo ob'ema//ANRI. 2024. № 3(118). S. 3-18. DOI:https://doi.org/10.37414/2075-1338-2024-118-3-318.
16. J. Wallis, T. Miller. «Three-dimensional display in nuclear medicine and radiology», J Nucl Med, no. 32(3), pp. 534-46, PMID 2005466, March 1991.
17. S. Napel, G. Rubin, R. Jeffrey, «STS-MIP: a new reconstruction technique for CT of the chest», Journal of computer assisted tomography, no. 17(5), pp. 832-8. 1993.