<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article
PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20190208//EN"
       "JATS-journalpublishing1.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="1.4" xml:lang="en">
 <front>
  <journal-meta>
   <journal-id journal-id-type="publisher-id">ANRI</journal-id>
   <journal-title-group>
    <journal-title xml:lang="en">ANRI</journal-title>
    <trans-title-group xml:lang="ru">
     <trans-title>АНРИ (Аппаратура и Новости Радиационных Измерений)</trans-title>
    </trans-title-group>
   </journal-title-group>
   <issn publication-format="print">2075-1338</issn>
  </journal-meta>
  <article-meta>
   <article-id pub-id-type="publisher-id">47527</article-id>
   <article-id pub-id-type="doi">10.37414/2075-1338-2021-107-4-41-51</article-id>
   <article-categories>
    <subj-group subj-group-type="toc-heading" xml:lang="ru">
     <subject>Научные статьи</subject>
    </subj-group>
    <subj-group subj-group-type="toc-heading" xml:lang="en">
     <subject>Scientific article</subject>
    </subj-group>
    <subj-group>
     <subject>Научные статьи</subject>
    </subj-group>
   </article-categories>
   <title-group>
    <article-title xml:lang="en">Adapted Method of Radiation Response Function Calculation for Development of High-Sensitivity Reference Meters Based on Scintillation Detection Units with NaI(Tl) Crystals for Dosimetry of Low-Intensity and Near-Background Levels</article-title>
    <trans-title-group xml:lang="ru">
     <trans-title>Адаптированный метод расчета функции радиационного отклика при создании высокочувствительных образцовых средств измерений на основе сцинтилляционных блоков детектирования с NaI(Tl) кристаллами для дозиметрии малоинтенсивных и околофоновых уровней</trans-title>
    </trans-title-group>
   </title-group>
   <contrib-group content-type="authors">
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Лукашевич</surname>
       <given-names>Роман В.</given-names>
      </name>
      <name xml:lang="en">
       <surname>Lukashevich</surname>
       <given-names>Raman V.</given-names>
      </name>
     </name-alternatives>
     <email>lukashevich@atomtex.com</email>
     <xref ref-type="aff" rid="aff-1"/>
    </contrib>
   </contrib-group>
   <aff-alternatives id="aff-1">
    <aff>
     <institution xml:lang="ru">Научно-производственное унитарное предприятие «АТОМТЕХ»</institution>
     <city>Минск</city>
     <country>Беларусь</country>
    </aff>
    <aff>
     <institution xml:lang="en">Scientific Production Unitary Enterprise «ATOMTEX»</institution>
     <city>Minsk</city>
     <country>Belarus</country>
    </aff>
   </aff-alternatives>
   <issue>4</issue>
   <fpage>41</fpage>
   <lpage>51</lpage>
   <history>
    <date date-type="received" iso-8601-date="2021-12-04T00:00:00+03:00">
     <day>04</day>
     <month>12</month>
     <year>2021</year>
    </date>
   </history>
   <self-uri xlink:href="https://doza.editorum.ru/en/nauka/article/47527/view">https://doza.editorum.ru/en/nauka/article/47527/view</self-uri>
   <abstract xml:lang="ru">
    <p>Метрологическое обеспечение полей фотонного излучения малоинтенсивных и околофоновых уровней (0,04–100 мкЗв/ч (мкГр§ч)) по мощности амбиентного эквивалента дозы или мощности кермы в воздухе с использованием сцинтилляционных детекторов с NaI(Tl) кристаллами выглядит перспективным и востребованным в дозиметрии, но нетривиальным ввиду сложной зависимости эффективности регистрации гамма-квантов от энергии. Решение подобных задач с применением данных детекторов может быть основано на применении функций радиационного отклика, являющихся функционалами от распределения флюенса поля излучения по энергиям.&#13;
В статье предложен адаптированный для решения задач метрологического обеспечения метод расчета функции радиационного отклика для создания высокоточных дозиметрических средств измерений на основе сцинтилляционных блоков детектирования с NaI(Tl) кристаллами.</p>
   </abstract>
   <trans-abstract xml:lang="en">
    <p>Metrological support of photon radiation fields of low-intensity and near-background levels (0.04–100 μSv/h (μGy/h)) by ambient equivalent dose rate or kerma rate in air using scintillation detectors with NaI(Tl) crystals looks promising and in demand in dosimetry, but nontrivial due to the complex dependence of efficiency registration of gamma quanta from energy. The solution of such problems with the use of these detectors can be based on the use of the radiation response functions, which are functionals of the energy distribution of the radiation field fluence.&#13;
The paper proposes a method for calculating the radiation response function adapted for solving metrological support problems for creating high-precision dosimetric measuring instruments based on scintillation detection units with NaI(Tl) crystals.</p>
   </trans-abstract>
   <kwd-group xml:lang="ru">
    <kwd>сцинтилляционный блок детектирования с NaI(Tl) кристаллом</kwd>
    <kwd>функция радиационного отклика</kwd>
    <kwd>метод Монте-Карло</kwd>
    <kwd>дозиметрия</kwd>
    <kwd>спектрометрический метод</kwd>
   </kwd-group>
   <kwd-group xml:lang="en">
    <kwd>scintillation detection unit with NaI(Tl) crystal</kwd>
    <kwd>radiation response function</kwd>
    <kwd>Monte Carlo method</kwd>
    <kwd>dosimetry</kwd>
    <kwd>spectrometric method</kwd>
   </kwd-group>
  </article-meta>
 </front>
 <body>
  <p></p>
 </body>
 <back>
  <ref-list>
   <ref id="B1">
    <label>1.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Государственная поверочная схема для средств измерений кермы в воздухе, мощности кермы в воздухе, экспозиционной дозы, мощности экспозиционной дозы, амбиентного, направленного и индивидуального эквивалентов дозы, мощностей амбиентного, направленного и индивидуального эквивалентов дозы и потока энергии рентгеновского и гамма-излучений. Введ. 31.12.20 приказом N№2314 Федеральным агентством по техническому регулированию и метрологии. М.: Росстандарт, 2020. 13 с.</mixed-citation>
     <mixed-citation xml:lang="en">Gosudarstvennaya poverochnaya shema dlya sredstv izmereniy kermy v vozduhe, moschnosti kermy v vozduhe, ekspozicionnoy dozy, moschnosti ekspozicionnoy dozy, ambientnogo, napravlennogo i individual'nogo ekvivalentov dozy, moschnostey ambientnogo, napravlennogo i individual'nogo ekvivalentov dozy i potoka energii rentgenovskogo i gamma-izlucheniy. Vved. 31.12.20 prikazom N№2314 Federal'nym agentstvom po tehnicheskomu regulirovaniyu i metrologii. M.: Rosstandart, 2020. 13 s.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B2">
    <label>2.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">S. Moriuchi. «A new method of dose evaluation by spectrum-dose conversion operator and determination of the operator», Japan Atomic Energy Research Inst. (JAERI), no. 1209, 35 p., 1971.</mixed-citation>
     <mixed-citation xml:lang="en">S. Moriuchi. «A new method of dose evaluation by spectrum-dose conversion operator and determination of the operator», Japan Atomic Energy Research Inst. (JAERI), no. 1209, 35 p., 1971.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B3">
    <label>3.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">S. Moriuchi et al. «Determination of spectrum-dose conversion operator for spherical NaI(Tl) scintillators», Japan Atomic Energy Research Inst. (JAERI-M), no. 8092, 46 p., 1979.</mixed-citation>
     <mixed-citation xml:lang="en">S. Moriuchi et al. «Determination of spectrum-dose conversion operator for spherical NaI(Tl) scintillators», Japan Atomic Energy Research Inst. (JAERI-M), no. 8092, 46 p., 1979.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B4">
    <label>4.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Фоминых В.И., Шульгович Г.И., Шульгович В.А. Кожемякин В.А. Измерение малых уровней гамма-излучения спектрометрическим методом с использованием оператора «спектр-доза»//Метрология. 1983. N 10. С. 32-39.</mixed-citation>
     <mixed-citation xml:lang="en">Fominyh V.I., Shul'govich G.I., Shul'govich V.A. Kozhemyakin V.A. Izmerenie malyh urovney gamma-izlucheniya spektrometricheskim metodom s ispol'zovaniem operatora «spektr-doza»//Metrologiya. 1983. N 10. S. 32-39.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B5">
    <label>5.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">S. Moriuchi, M. Tsutsumi, K. Saito. «Development of a dosimetric system using spectrometric technique suitable for operational radiation dose measurements and evaluation». 10-th Intern. congress of the International Radiation Protection Association IRPA-10: proc. congress, Hiroshima, 14-19 May 2000. Japan Health Physics Society, Tokyo, pp. 3b-197, 2000.</mixed-citation>
     <mixed-citation xml:lang="en">S. Moriuchi, M. Tsutsumi, K. Saito. «Development of a dosimetric system using spectrometric technique suitable for operational radiation dose measurements and evaluation». 10-th Intern. congress of the International Radiation Protection Association IRPA-10: proc. congress, Hiroshima, 14-19 May 2000. Japan Health Physics Society, Tokyo, pp. 3b-197, 2000.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B6">
    <label>6.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">K. Saito, S. Moriuchi, «Monte Carlo calculation of accurate response functions for a NaI(Tl) detector for gamma rays», Nuclear instruments and methods., no. 185, pp. 299-308, 1981.</mixed-citation>
     <mixed-citation xml:lang="en">K. Saito, S. Moriuchi, «Monte Carlo calculation of accurate response functions for a NaI(Tl) detector for gamma rays», Nuclear instruments and methods., no. 185, pp. 299-308, 1981.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B7">
    <label>7.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">G. Cho, H.K. Kim, H. Woo, «Electronic dose conversion technique using a NaI(Tl) detector for assessment of exposure dose rate from environmental radiation», IEEE Transactions on Nuclear Science, no. 45, pp. 981-985, 1998.</mixed-citation>
     <mixed-citation xml:lang="en">G. Cho, H.K. Kim, H. Woo, «Electronic dose conversion technique using a NaI(Tl) detector for assessment of exposure dose rate from environmental radiation», IEEE Transactions on Nuclear Science, no. 45, pp. 981-985, 1998.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B8">
    <label>8.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">K. Saito, S. Moriuchi, «Monte Carlo calculation of NaI(Tl) detector response functions for low energy gamma rays», Nuclear instruments and methods, no. 226, pp. 449-454, 1984.</mixed-citation>
     <mixed-citation xml:lang="en">K. Saito, S. Moriuchi, «Monte Carlo calculation of NaI(Tl) detector response functions for low energy gamma rays», Nuclear instruments and methods, no. 226, pp. 449-454, 1984.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B9">
    <label>9.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">K. Aoyama et al. «Development of low-energy x-ray survey-meter, radiation detectors and their uses», KEK Proceedings, no. 7, pp. 57-67, 2006.</mixed-citation>
     <mixed-citation xml:lang="en">K. Aoyama et al. «Development of low-energy x-ray survey-meter, radiation detectors and their uses», KEK Proceedings, no. 7, pp. 57-67, 2006.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B10">
    <label>10.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">S. Yamamura et al., «Development of wide-energy range X/gamma-ray survey-meter», Journal of Nuclear Science and Technology, vol. 45, iss. 5, pp. 187-190, 2008.</mixed-citation>
     <mixed-citation xml:lang="en">S. Yamamura et al., «Development of wide-energy range X/gamma-ray survey-meter», Journal of Nuclear Science and Technology, vol. 45, iss. 5, pp. 187-190, 2008.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B11">
    <label>11.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Лукашевич Р.В., Фоков Г.А. Применение спектрометрического метода расчета мощности дозы для создания высокочувствительных образцовых средств измерений на базе сцинтилляционных блоков детектирования//Приборы и методы измерений. 2017. N 8(3). C. 246-253. URL: https://doi.org/10.21122/2220-9506-2017-8-3-246-253 (дата обращения: 27.07.2021).</mixed-citation>
     <mixed-citation xml:lang="en">Lukashevich R.V., Fokov G.A. Primenenie spektrometricheskogo metoda rascheta moschnosti dozy dlya sozdaniya vysokochuvstvitel'nyh obrazcovyh sredstv izmereniy na baze scintillyacionnyh blokov detektirovaniya//Pribory i metody izmereniy. 2017. N 8(3). C. 246-253. URL: https://doi.org/10.21122/2220-9506-2017-8-3-246-253 (data obrascheniya: 27.07.2021).</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B12">
    <label>12.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Survey Meter NHC6/NHC7. URL: https://geigercounter001.blog.fc2.com/blog-entry-1057.html (дата обращения: 13.07.2021).</mixed-citation>
     <mixed-citation xml:lang="en">Survey Meter NHC6/NHC7. URL: https://geigercounter001.blog.fc2.com/blog-entry-1057.html (data obrascheniya: 13.07.2021).</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B13">
    <label>13.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">R. Lukashevich, M. Korhzik, A. Gektin. «Application scintillation comparators for calibration low intense gamma radiation fields by dose rate in the range of 0,03-0,1 μSv/h»; (eds), «Engineering of scintillation materials and radiation technologies», Springer Proceedings Phys., vol. 227, pp. 221-235. URL: https://doi.org/10.1007/978-3-030-21970-3_16 (дата обращения: 31.08.2021).</mixed-citation>
     <mixed-citation xml:lang="en">R. Lukashevich, M. Korhzik, A. Gektin. «Application scintillation comparators for calibration low intense gamma radiation fields by dose rate in the range of 0,03-0,1 μSv/h»; (eds), «Engineering of scintillation materials and radiation technologies», Springer Proceedings Phys., vol. 227, pp. 221-235. URL: https://doi.org/10.1007/978-3-030-21970-3_16 (data obrascheniya: 31.08.2021).</mixed-citation>
    </citation-alternatives>
   </ref>
  </ref-list>
 </back>
</article>
