<?xml version="1.0"?>
<!DOCTYPE article
PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20190208//EN"
       "JATS-journalpublishing1.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="1.4" xml:lang="en">
 <front>
  <journal-meta>
   <journal-id journal-id-type="publisher-id">ANRI</journal-id>
   <journal-title-group>
    <journal-title xml:lang="en">ANRI</journal-title>
    <trans-title-group xml:lang="ru">
     <trans-title>АНРИ (Аппаратура и Новости Радиационных Измерений)</trans-title>
    </trans-title-group>
   </journal-title-group>
   <issn publication-format="print">2075-1338</issn>
  </journal-meta>
  <article-meta>
   <article-id pub-id-type="publisher-id">92295</article-id>
   <article-id pub-id-type="doi">10.37414/2075-1338-2024-119-4-35-42</article-id>
   <article-categories>
    <subj-group subj-group-type="toc-heading" xml:lang="ru">
     <subject>Научные статьи</subject>
    </subj-group>
    <subj-group subj-group-type="toc-heading" xml:lang="en">
     <subject>Scientific article</subject>
    </subj-group>
    <subj-group>
     <subject>Научные статьи</subject>
    </subj-group>
   </article-categories>
   <title-group>
    <article-title xml:lang="en">Estimation of Uncertainty in Measurements of Dosimetric Characteristics of Photon Fields Generated by Linear Electron Accelerators</article-title>
    <trans-title-group xml:lang="ru">
     <trans-title>Оценка неопределенности при измерениях дозиметрических характеристик фотонных полей линейных ускорителей электронов</trans-title>
    </trans-title-group>
   </title-group>
   <contrib-group content-type="authors">
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Лазаренко</surname>
       <given-names>С. В.</given-names>
      </name>
      <name xml:lang="en">
       <surname>Lazarenko</surname>
       <given-names>Sergey V.</given-names>
      </name>
     </name-alternatives>
     <xref ref-type="aff" rid="aff-1"/>
    </contrib>
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Тараев</surname>
       <given-names>А. Ю.</given-names>
      </name>
      <name xml:lang="en">
       <surname>Taraev</surname>
       <given-names>Aleksandr Yu.</given-names>
      </name>
     </name-alternatives>
     <xref ref-type="aff" rid="aff-2"/>
    </contrib>
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Загороднюк</surname>
       <given-names>А. А.</given-names>
      </name>
      <name xml:lang="en">
       <surname>Zaharadniuk</surname>
       <given-names>Aliaksei A.</given-names>
      </name>
     </name-alternatives>
     <email>fiz.zagorodnAA@gmail.com</email>
     <xref ref-type="aff" rid="aff-3"/>
     <xref ref-type="aff" rid="aff-4"/>
    </contrib>
   </contrib-group>
   <aff-alternatives id="aff-1">
    <aff>
     <institution xml:lang="ru">Научно-производственное унитарное предприятие «АТОМТЕХ»</institution>
     <city>Минск</city>
     <country>Беларусь</country>
    </aff>
    <aff>
     <institution xml:lang="en">Scientific Production Unitary Enterprise «ATOMTEX»</institution>
     <city>Minsk</city>
     <country>Belarus</country>
    </aff>
   </aff-alternatives>
   <aff-alternatives id="aff-2">
    <aff>
     <institution xml:lang="ru">Научно-производственное унитарное предприятие «АТОМТЕХ»</institution>
     <city>Минск</city>
     <country>Беларусь</country>
    </aff>
    <aff>
     <institution xml:lang="en">Scientific Production Unitary Enterprise «ATOMTEX»</institution>
     <city>Minsk</city>
     <country>Belarus</country>
    </aff>
   </aff-alternatives>
   <aff-alternatives id="aff-3">
    <aff>
     <institution xml:lang="ru">Научно-производственное унитарное предприятие «АТОМТЕХ»</institution>
     <city>Минск</city>
     <country>Беларусь</country>
    </aff>
    <aff>
     <institution xml:lang="en">Scientific Production Unitary Enterprise «ATOMTEX»</institution>
     <city>Minsk</city>
     <country>Belarus</country>
    </aff>
   </aff-alternatives>
   <aff-alternatives id="aff-4">
    <aff>
     <institution xml:lang="ru">Белорусский государственный университет</institution>
    </aff>
    <aff>
     <institution xml:lang="en">Belarusian State University</institution>
    </aff>
   </aff-alternatives>
   <pub-date publication-format="print" date-type="pub" iso-8601-date="2024-12-19T22:57:41+03:00">
    <day>19</day>
    <month>12</month>
    <year>2024</year>
   </pub-date>
   <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2024-12-19T22:57:41+03:00">
    <day>19</day>
    <month>12</month>
    <year>2024</year>
   </pub-date>
   <issue>4</issue>
   <fpage>35</fpage>
   <lpage>42</lpage>
   <history>
    <date date-type="received" iso-8601-date="2024-12-19T00:00:00+03:00">
     <day>19</day>
     <month>12</month>
     <year>2024</year>
    </date>
   </history>
   <self-uri xlink:href="https://doza.editorum.ru/en/nauka/article/92295/view">https://doza.editorum.ru/en/nauka/article/92295/view</self-uri>
   <abstract xml:lang="ru">
    <p>В статье рассмотрены основные компоненты бюджета неопределенности при измерении средней мощности амбиентного эквивалента дозы H ∗ (10 ) (далее – СМАЭД), генерируемого медицинским линейным ускорителем электронов (далее – ЛУЭ). Бюджет неопределенности СМАЭД составлен для случая проверки работоспособности дозиметрического оборудования в полях импульсного микросекундного фотонного излучения, генерируемых ЛУЭ согласно методике, описанной в работах [1,2,3,4]. Оценка неопределенности СМАЭД, генерируемой ЛУЭ в точке измерения, производилась по процедуре, описанной в ГОСТ 34100.3.2-2017 [5]. Согласно данной схеме, на первом этапе происходило определение базовой дозиметрической величины – мощности кермы в воздухе (далее – мощность кермы), генерируемой ЛУЭ в заданной точке, путем измерений эталонным дозиметром ДКСАТ5350/1 в составе с ионизационной камерой TM32002 (далее – ИК). На втором этапе был произведен перерасчет мощности кермы в СМАЭД с помощью переходного коэффициента (который в общем случае зависит от энергии излучения) согласно СТБ ИСО 4037-3-2022 [6]. Оценка неопределенности после каждого этапа происходила исходя из явного вида выражения, связывающего входные и выходные параметры (ток – мощность кермы для первого этапа, мощность кермы – СМАЭД для второго этапа). Установлено, что неопределенность измерения СМАЭД, генерируемой ЛУЭ в точке измерения, рассчитанная согласно выше описанной схеме, не превышает 13% для всех режимов работы ЛУЭ.</p>
   </abstract>
   <trans-abstract xml:lang="en">
    <p>The article considers the main components of the uncertainty budget when measuring the average ambient dose equivalent rate H*(10) (or ADE for short) generated by a medical linear electron accelerator (or LINAC for short). The budget of the ADE uncertainty is made for the case of assessment of the performance of dosimetric equipment in the fields of pulsed microsecond photon radiation generated by LINAC according to the method described in [1,2,3,4]. The estimation of the ADE uncertainty generated by LINAC at the measurement point was performed according to the procedure described in GOST 34100.3.2-2017 [5]. According to this scheme, at the first stage the determination of the basic dosimetric quantity – kerma rate in air (or kerma rate for short), generated by LINAC at a given point, was performed by using the reference dosimeter DKS AT5350/1 in combination with the ionization chamber TM32002. At the second stage, the kerma rate was converted to the ADE using the conversion coefficient according to STB ISO 4037-3-2022 [6]. The uncertainty estimation after each stage was based on the explicit form of the expression inking the input and output parameters (current – kerma rate for the first stage, kerma rate – ADE for the second stage). It was found that the uncertainty of the ADE generated by the LINAC at the measurement point, calculated according to the above described scheme, does not exceed 13% for all operating modes of the LINAC.</p>
   </trans-abstract>
   <kwd-group xml:lang="ru">
    <kwd>линейный ускоритель электронов</kwd>
    <kwd>импульсное фотонное излучение</kwd>
    <kwd>калибровка дозиметра</kwd>
    <kwd>неопределенность измерений.</kwd>
   </kwd-group>
   <kwd-group xml:lang="en">
    <kwd>LINAC</kwd>
    <kwd>pulsed photon radiation</kwd>
    <kwd>dosimeter calibration</kwd>
    <kwd>uncertainty</kwd>
   </kwd-group>
  </article-meta>
 </front>
 <body>
  <p></p>
 </body>
 <back>
  <ref-list>
   <ref id="B1">
    <label>1.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Загороднюк А.А., Тараев А.Ю., Лазаренко С.В., Комар Д.И. Влияние свинцового фильтра на среднюю энергию фотонного излучения медицинского линейного ускорителя электронов//АНРИ. 2023. №№2(113). С. 13-24.</mixed-citation>
     <mixed-citation xml:lang="en">Zagorodnyuk A.A., Taraev A.Yu., Lazarenko S.V., Komar D.I. Vliyanie svincovogo fil'tra na srednyuyu energiyu fotonnogo izlucheniya medicinskogo lineynogo uskoritelya elektronov//ANRI. 2023. №№2(113). S. 13-24.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B2">
    <label>2.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Загороднюк А.А., Тараев А.Ю., Лазаренко С.В. О возможности использования медицинских линейных ускорителей электронов в качестве поля эталонного импульсного фотонного излучения//Приборы и методы измерений. 2023. Т. 14, №№3. С. 179-190.</mixed-citation>
     <mixed-citation xml:lang="en">Zagorodnyuk A.A., Taraev A.Yu., Lazarenko S.V. O vozmozhnosti ispol'zovaniya medicinskih lineynyh uskoriteley elektronov v kachestve polya etalonnogo impul'snogo fotonnogo izlucheniya//Pribory i metody izmereniy. 2023. T. 14, №№3. S. 179-190.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B3">
    <label>3.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Тараев А.Ю., Загороднюк А.А., Богдан М.А., Лазаренко С.В. Оценка характеристик полей фотонного излучения медицинских линейных ускорителей электронов различных производителей// AНРИ. 2023. №№4(115). С. 19-31.</mixed-citation>
     <mixed-citation xml:lang="en">Taraev A.Yu., Zagorodnyuk A.A., Bogdan M.A., Lazarenko S.V. Ocenka harakteristik poley fotonnogo izlucheniya medicinskih lineynyh uskoriteley elektronov razlichnyh proizvoditeley// ANRI. 2023. №№4(115). S. 19-31.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B4">
    <label>4.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Тараев А.Ю., Загороднюк А.А., Лазаренко С.В., Масюкович М.В. Оценка функционирования дозиметрического оборудования при проведении измерений в полях импульсного микросекундного фотонного излучения с известными характеристиками//АНРИ. 2024. №№2(117). С. 17-26.</mixed-citation>
     <mixed-citation xml:lang="en">Taraev A.Yu., Zagorodnyuk A.A., Lazarenko S.V., Masyukovich M.V. Ocenka funkcionirovaniya dozimetricheskogo oborudovaniya pri provedenii izmereniy v polyah impul'snogo mikrosekundnogo fotonnogo izlucheniya s izvestnymi harakteristikami//ANRI. 2024. №№2(117). S. 17-26.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B5">
    <label>5.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">ГОСТ 34100.3.2-2017. Неопределенность измерения. Часть 3. Руководство по выражению неопределенности измерения. Дополнение 2. Обобщение на случай произвольного числа выходных величин. Введ. 2018-09-01. М., 2018. 72 c.</mixed-citation>
     <mixed-citation xml:lang="en">GOST 34100.3.2-2017. Neopredelennost' izmereniya. Chast' 3. Rukovodstvo po vyrazheniyu neopredelennosti izmereniya. Dopolnenie 2. Obobschenie na sluchay proizvol'nogo chisla vyhodnyh velichin. Vved. 2018-09-01. M., 2018. 72 c.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B6">
    <label>6.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">СТБ ИСО 4037-3-2022. Защита радиологическая. Эталонные рентгеновские и гамма-излучения для калибровки дозиметров и измерителей мощности дозы и определения их отклика как функции энергии фотона. Часть 3. Калибровка дозиметров окружающей среды и индивидуальных дозиметров и измерение их отклика в зависимости от энергии и угла падения излучения. Введ. 22-11-01. Мн., 2022. 58 с.</mixed-citation>
     <mixed-citation xml:lang="en">STB ISO 4037-3-2022. Zaschita radiologicheskaya. Etalonnye rentgenovskie i gamma-izlucheniya dlya kalibrovki dozimetrov i izmeriteley moschnosti dozy i opredeleniya ih otklika kak funkcii energii fotona. Chast' 3. Kalibrovka dozimetrov okruzhayuschey sredy i individual'nyh dozimetrov i izmerenie ih otklika v zavisimosti ot energii i ugla padeniya izlucheniya. Vved. 22-11-01. Mn., 2022. 58 s.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B7">
    <label>7.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">IEC/TS 63050:2019. Radiation protection instrumentation – Dosimeters for pulsed fields of ionizing radiation.</mixed-citation>
     <mixed-citation xml:lang="en">IEC/TS 63050:2019. Radiation protection instrumentation – Dosimeters for pulsed fields of ionizing radiation.</mixed-citation>
    </citation-alternatives>
   </ref>
  </ref-list>
 </back>
</article>
